Build first, perfuse later: open-top biochips for complex organ-on-chip models
Organ-on-chip technology has transformed the way researchers model human organ functions in vitro. By combining essential cellular components with controlled microfluidic perfusion, organ-on-chip systems can recreate key aspects of human physiology that are difficult to capture in simple 2D cell cultures or animal models.
As organ-on-chip models become increasingly complex and physiologically relevant, conventional closed chip formats can introduce a practical limitation: direct access to the culture area.
Many advanced biological models cannot simply be introduced into a sealed biochip through an inlet or channel. Large explant samples, patient-derived biopsies, bioprinted constructs, viscous drug depots and functional sensors often need to be positioned directly within the culture chamber.
By keeping the cell culture chamber accessible during model preparation, open-top biochips offer a fundamentally different approach. They enable the integration of materials that would otherwise be difficult, or in some cases impossible, to incorporate into a conventional sealed biochip.
In this article, we explore four application areas of open-top biochips that illustrate how accessible biochip designs open new possibilities in organ-on-chip experiments: 3D bioprinting, tissue slice culture, drug delivery systems, and functional interfaces for advanced sensing and analysis.

1. Bioprinting
3D bioprinting is emerging as a powerful technology for developing increasingly complex, spatially resolved organ-on-chip models. Unlike conventional cell seeding, bioprinting enables the controlled spatial deposition of cells and biomaterials, allowing researchers to create tissue structures with defined two- and three-dimensional architectures. Commonly, cell-laden bioinks, such as collagen-, fibrin-, gelatin- or alginate-hydrogels, are extruded through a nozzle and deposited layer by layer and subsequently stabilized. By employing exchangeable printheads and different materials, it enables researchers to create realistic tissues with superior spatial resolution and cellular heterogeneity.
However, the more complex the printed construct, the more important it becomes to minimize subsequent handling. Transferring the delicate, cell-laden hydrogel from a printer to a separate microfluidic device can alter its architecture, introduce mechanical stress or make precise positioning more difficult.
Open-top biochips address this challenge by allowing the biological construct to be printed directly into the microfluidic culture chamber. The nozzle has unrestricted access during printing, while the chamber can subsequently be sealed and connected to controlled perfusion.

The open architecture does more than simplify the workflow: it enables a direct transition from 3D tissue fabrication to dynamic microfluidic culture without requiring the printed construct to be transferred between devices, therefore minimizing the risk of contamination and compromising tissue quality.
A representative example was reported by Abudupataer et al.[1], who developed a biomimetic vessel-on-chip system using an open microfluidic platform. Two layers of cell-laden hydrogel containing human aortic smooth muscle cells (HASMCs) and human aortic endothelial cells (HAESCs) were directly printed into an open microfluidic chip. After printing, the channel was sealed with a PMMA slide using double-sided adhesive tape and perfusion was initiated. Immunofluorescence analysis showed enhanced expression of cell-specific markers, including αSMA and SM22, in the perfused co-culture compared with 2D culture.
Other studies have similarly demonstrated the direct integration of bioprinted constructs into microfluidic devices. For example, Chang et al.[2] used extrusion printing to introduce alignate-encapsulated HepG2 cells into a prefabricated chamber of a PDMS chip to study in vitro drug metabolism in a 3D liver-on-chip model. The device was sealed with a glass cover containing microfluidic channels to enable perfusion.
These examples illustrate a fundamental benefit of open-top biochips: complex tissue constructs can be created directly where they will ultimately be cultured, without being constrained by the channel geometry of the biochip.
2. Tissue slice culture
Open access is equally relevant when researchers work with intact biological samples that cannot easily be introduced into a closed microfluidic channel, such as organotypic tissue slices, explants or patient-derived tissue.
Tissue slice culture provides a valuable ex vivo approach because it preserves aspects of the native tissue architecture and cellular organization. However, once tissue is removed from the body, vascular perfusion is lost and oxygen, nutrients and drugs must reach the tissue largely by diffusion. These limitations can lead to concentration gradients, tissue stress and declining viability over time — particularly in thicker tissue samples.
Open-top biochips offer a way to combine the biological relevance of intact tissue with the benefits of dynamic perfusion. The tissue can be positioned directly in an accessible culture area, and can be sealed afterwards to allow for perfusion, either submerged or at an air-liquid interface.

The potential of this approach has been demonstrated in several explant models.[3-6]
A relevant example is the recent work of Abdrés-Rosa et al.[5], who investigated human cirrhotic precision-cut liver slices (hPCLS) under static and microfluidic conditions. Using an open, modular microfluidic device, the researchers cultured the tissue for seven days and evaluated parameters including viability, necrosis, fibrosis and liver function.
Compared to static culture, microfluidic perfusion was associated with improved tissue integrity, more stable cell proliferation and reduced necrosis, while preserving cellular interactions. The researchers also observed differences in the progression of fibrosis: while fibrosis increased over time in static conditions, it remained stable under microfluidic conditions, preserving the cirrhotic phenotype for further drug evaluations. These findings indicate that dynamic perfusion may help preserve both tissue viability and disease-relevant characteristics in cirrhotic liver slices.
Moving to cancer research, Chakrabarty et al. [6] demonstrated the benefits of dynamic tissue culture for treatment-response testing using breast and prostate tumor slices. The researchers placed the tumor slices on a porous membrane inside the open cultivation chamber and sealed the chamber using a top plate containing microfluidic fittings to connect a pumping system. This cancer-on-chip platform maintained the viability and proliferation of the tumor slice for seven days without major changes in tissue morphology or gene expression patterns.
Together, these examples illustrate why access to the culture chamber is an essential consideration when working with dynamic organotypic cultures. An open microfluidic platform allows larger tissue slices to be positioned directly within the culture chamber before the system is sealed and perfused, enabling researchers to preserve the viability of valuable tissue slices for longer periods.
3. Drug delivery systems
Organ-on-chip technology is increasingly used to study drug transport, metabolism and toxicity for drug development. Yet, many therapeutic approaches require the active compound to be released at a specific time and location within the human body to efficiently effect their target.
Drug delivery systems (DDS) are formulations that are designed to control the location, timing and release rate of a therapeutic substance. They range from lipid-based nanoparticles to polymeric hydrogels or anorganic and carbon-based DDS.[7]

Organ-on-chip technology is a valuable platform for studying DDS by providing physiologically relevant human models that mimic human response towards drug carriers. However, for some applications, the challenge is not necessarily establishing the suitable organ model but rather integrating the DDS into the microfluidic environment.
Small DDS, such as lipid or metallic nanoparticles can often be introduced directly through microfluidic channels. Larger or highly viscous systems, such as hydrogel-based drug depots, are more difficult to distribute through narrow inlet ports. An open culture chamber provides an alternative: the drug depot can be positioned directly in the culture chamber location before the biochip is sealed and perfused.
Surface-based systems are typically deposited on a substrate layer-by-layer forming drug-loaded nanofilms. Open-top biochips allow researchers to prepare surface-functionalized substrates independently and incorporate them into the chip before the sealing step.[8]
The same concept can be applied to topical and transdermal drug delivery. Skin-on-chip models are frequently used for in vitropermeation studies to test the capability of topical drugs to pass through the cutaneous barrier. An open microfluidic configuration allows in vitro skin models or skin explants to be integrated and cultivated in an air-liquid interface. At the same time, a topical formulation can be applied directly on top of the epithelial surface to mimic drug passage in a more realistic, physiologically relevant barrier model.[9]
4. Functional interfaces for advanced sensing and analysis
The potential of an open chip design extends beyond the integration of biological samples. The ability to access the chip and its components before final assembly also creates opportunities to introduce additional analytical and functional elements.
Surfaces can, for example, be modified before sealing to introduce specific surface properties (anti-fouling, increased wettability) or to immobilize biomolecules such as antibodies or nucleic acids to capture specific analytes within the medium [10].

Sensors represent another important application [11]. Monitoring cultivation parameters such as oxygen levels, pH or temperature can provide valuable information about the local microenvironment in organ models. Commercially available platforms with integrated sensor technology enable monitoring of crucial parameters of culture viability in standard closed-chip platforms, including oxygen and TEER measurements.
Open-top biochips may enable the combination of cultivating of 3D printed constructs or large explant cultures with real-time measurement of these parameters. By depositing sensor elements in a desired location of the sealing substrate, sensor integration is possible while sealing the biochip. The same concept can be extended to other sensing technologies and analytical questions. Depending on the experimental requirements, the accessible interfaces of an open platform give flexibility to accommodate sensors, immobilized biomolecules, surface modifications or other functional elements.
From a closed device to a flexible research platform
Across these four application areas, the same challenge emerges: complex biological models often require chamber access before starting perfusion.
Whether researchers are printing a tissue, positioning a patient-derived explant, integrating a drug depot or adding a surface functionalization, the ability to configure the culture environment before sealing can be essential to establish a realistic organ model and retrieve relevant data to answer complex research questions.
Open-top biochips create a simple but powerful modification of the standard sealed-chip workflow: First, the model is built in an accessible chamber; then, the system is sealed and dynamic perfusion is introduced.
As organ-on-chip and biofabrication technologies continue to evolve, biological models are becoming increasingly complex. Meeting this complexity does not only require more sophisticated microfluidic systems; it also requires platforms that provide researchers with the freedom to build and adapt the model before the system is closed.
And sometimes, the key to a more advanced microfluidic model is simply to leave the chip open until the model is ready to be sealed.
References
Bioprinting
[1] Abudupataer M, Chen N, Yan S, et al. Bioprinting a 3D vascular construct for engineering a vessel-on-a-chip. Biomed Microdevices. 2019;22(1):10. Published 2019 Dec 26. doi:10.1007/s10544-019-0460-3
[2] Chang R, Emami K, Wu H, Sun W. Biofabrication of a three-dimensional liver micro-organ as an in vitro drug metabolism model. Biofabrication. 2010;2(4):045004. doi:10.1088/1758-5082/2/4/045004
Tissue Slice Culture
[3] Baydoun M, Treizeibré A, Follet J, et al. An Interphase Microfluidic Culture System for the Study of Ex Vivo Intestinal Tissue. Micromachines (Basel). 2020;11(2):150. Published 2020 Jan 30. doi:10.3390/mi11020150
[4] Bakmand T, Troels-Smith AR, Dimaki M, et al. Fluidic system for long-term in vitro culturing and monitoring of organotypic brain slices. Biomed Microdevices. 2015;17(4):71. doi:10.1007/s10544-015-9973-6
[5] Andrés-Rozas M, Aristu-Zabalza P, Chullo G, et al. Microfluidic human liver slices reveal antifibrotic effects of liraglutide via HSC deactivation and ECM remodeling. Biomed Pharmacother. 2026;201:119711. doi:10.1016/j.biopha.2026.119711
[6] Chakrabarty S, Quiros-Solano WF, Kuijten MMP, et al. A Microfluidic Cancer-on-Chip Platform Predicts Drug Response Using Organotypic Tumor Slice Culture. Cancer Res. 2022;82(3):510-520. doi:10.1158/0008-5472.CAN-21-0799
Drug delivery systems
[7] Tiwari G, Tiwari R, Sriwastawa B, et al. Drug delivery systems: An updated review. Int J Pharm Investig.2012;2(1):2-11. doi:10.4103/2230-973X.96920
[8] Wang J, Sui T, Ma Y, et al. Evidence architecture of glaucoma-related biomaterials reveals an uneven transition toward smart materials, additive manufacturing, and functional tissue engineering. Front Bioeng Biotechnol. 2026;14:1868297. doi:10.3389/fbioe.2026.1868297
[9] Tavares RSN, Tao TP, Maschmeyer I, et al. Toxicity of topically applied drugs beyond skin irritation: Static skin model vs. Two organs-on-a-chip. Int J Pharm. 2020;589:119788. doi:10.1016/j.ijpharm.2020.119788
Functional interfaces
[10] Shakeri A, Jarad NA, Khan S, F Didar T. Bio-functionalization of microfluidic platforms made of thermoplastic materials: A review. Anal Chim Acta. 2022;1209:339283. doi:10.1016/j.aca.2021.339283
More interesting articles:
Blog, Tissue Slice Culture
Build first, perfuse later: open-top biochips for complex organ-on-chip models
In organ-on-chip models the coating plays a central role to support cell attachment, survival, differentiation, and tissue-specific function.
Read MoreBlog
How to choose the right membrane coating for your organ-on-chip model?
In organ-on-chip models the coating plays a central role to support cell attachment, survival, differentiation, and tissue-specific function.
Read MoreBlog, Disease-Modeling, Gut-on-Chip, Infection-Modeling
When butyrate drops, the gut loses more than a metabolite – it loses resilience
In this new study by Manuel Allwang, Maximilian Wipplinger, and Parastoo Akbarimoghaddam and colleagues, published in Small, the authors show why that loss may be especially important when inflamed tissue is challenged by the opportunistic fungus Candida albicans.
Read More